Allokat 20 - Allokat 160
For installations on a pilot scale or small production, catalytic oxidation is often the most economic way to clean the exhaust air from organic compounds. With low investment and operating costs and minimal space requirements, the emission can comply with the given emission limits reliably and durably.
The standard modules Allokat 20 to Allokat 160 can be used in the installation of new production facilities, but are often retrofitted on existing units.
*) with heat exchanger at max. volumetric flow rate
Allokat 20 | Allokat 80 | Allokat 160 | ||
power | kW | 1,5 | 9 | 18 |
volumetric flow rate max. | m3/h | 20 | 80 | 160 |
organic concentration max. | g/m3 | 10 | 10 | 10 |
organic mass flow rate max | g/min | 2,5 | 13 | 26 |
required org. mass flow for autothermal operation * | g/min | 3 | 5 | 10 |
outer dimensions without accessories | mm3 | 200 x 250 x 800 | 450 x 470 x 2000 | 450 x 550 x 2000 |
weight | kg | 20 | 55 | 65 |